Functional Safety for Your Industry

SIListra Systems supports companies in automation and the process industry, robotics, heavy equipment and machinery in implementing safety functions in a software-based, portable and certified manner. Discover how SIListra Systems supports your industry.

TÜV SÜD-certified SIL 3 (IEC 61508, 62061, 61511) PL e (ISO 13849) ASIL D (ISO 26262)

Industries Overview

Automation

Safety PLCs and virtual PLCs, sensors and safe communication, process industry (IEC 61511)

Learn more: Automation

Robotics

Robot arms, AGVs and AMRs, safe motion and drives, floating point, high computing power

Learn more: Robotics

Heavy Equipment

Cranes, excavators, underground machines, stage machinery, floating point, platform changes

Learn more: Heavy Equipment

Machinery

Packaging machines, machine tools, special-purpose machinery, IEC 62061 and ISO 13849

Learn more: Machinery

Typical Use Cases

Typical situations and projects in which SIListra Systems is particularly useful – and how a software-based, portable, and certified safety solution addresses the challenges they bring.

Migration to New Hardware Platforms

Situation: A company needs to switch its control hardware because the old platform is being discontinued or new requirements exist.
Challenge: Classic safety solutions often require a complete redevelopment and recertification.
SIListra Systems Advantage: Safety logic built with the SIListra Safety Transformer stays portable and reusable – without full recertification.

Virtualization of Controllers

Situation: Control functions are increasingly operated as software (e.g., virtual PLC) on standard hardware or in the cloud.
Challenge: Safety must be ensured independent of specific hardware.
SIListra Systems Advantage: The SIListra Safety Transformer enables certified safety functions on virtualized or software-defined architectures.

Integrating Safety into Existing Software Architectures

Situation: A manufacturer wants to integrate safety functions into an existing, complex software architecture.
Challenge: Classic safety modules are often difficult to integrate and not flexible enough.
SIListra Systems Advantage: The SIListra Safety Transformer is designed as a development tool and technology component that can be integrated into customer-specific software architectures.

Portability and Reusability of Safety Logic

Situation: A company wants to reuse safety functions across products, product generations or hardware platforms.
Challenge: Reusability is hardly possible with classic safety solutions.
SIListra Systems Advantage: Safety logic built with the SIListra Safety Transformer is portable across platforms and can be reused in various projects/products.

Safety Functions in New Products

Situation: A manufacturer is developing a new product with safety requirements.
Challenge: Traditionally, safety means custom development and certification.
SIListra Systems Advantage: With the SIListra Safety Transformer, the path to a certified product is faster – with a TÜV SÜD-certified development tool and safety logic you can reuse across products.

SIListra Systems vs. Traditional Approach

Traditional safety architectures quickly reach their limits with hardware changes, virtualization, and further development. The SIListra Systems approach enables certified, software-based functional safety – portable, flexible, and future-proof.

Criterion
SIListra Systems Approach
Traditional Safety Architecture
Hardware dependency
✓Safety is implemented in software and runs on standard (COTS) hardware, e.g. industrial PCs, edge cloud servers or non-safety PLCs. Portability is ensured.
✗Safety functions are tightly bound to specific two-channel hardware. Hardware changes are costly and time-consuming.
Operating system & software
✓A standard operating system, e.g. Linux, with safe separation from non-safety software.
✗A safety operating system or bare-metal embedded safety software.
Safety mechanisms
✓A safe clock and the black channel – everything else is provided by Coded Processing.
✗Besides a safe clock and the black channel, cyclic RAM checks, hardware checks and program flow control have to be implemented.
Security
✓Security with standard software (e.g. SSH, OpenSSL, SELinux), updated independently of the safety function.
✗Safety and security are tightly coupled and need custom solutions.
Portability & migration
✓Safety logic can be ported to new hardware or virtual environments – without full re-certification.
✗Migrating to new platforms often requires redevelopment and re-certification.
Certification
✓TÜV SÜD-certified development tool (IEC 61508 SIL 3, ISO 26262 ASIL D, ISO 13849 PL e), with clear evidence and documentation.
✗Costly, hardware-bound certification processes.
Flexibility & future-proofing
✓Enables virtualization, software-defined architectures, and long-term evolution.
✗Limited flexibility for further development and virtualization.
Integration effort
✓A development tool and technology building block that integrates into customer-specific software architectures.
✗Integration into existing software architectures is complex and often only possible to a limited extent.
Reusability
✓Safety logic is reusable and can be applied across different projects/products.
✗Safety functions are usually not reusable.
Transparency & traceability
✓Explainable, documented error detection (Coded Processing, SIListra Safety Transformer), traceable architecture.
✗Often has a black-box character, hard for software developers to explain.
Cost & effort
✓Reduced costs through portability, reusability, and software-based certification.
✗High costs due to hardware binding, redevelopment, and certification.

Common Questions from Our Industries

Which standards does the certificate cover for my industry? +−
The SIListra Safety Transformer is TÜV SÜD-certified for IEC 61508 up to SIL 3 as the generic standard; for machinery, ISO 13849 up to PL e (Cat. 3 and 4) and IEC 62061 up to SIL 3; for the process industry, IEC 61511 up to SIL 3; and for road vehicles, ISO 26262 up to ASIL D. See Certification & Standards.
Can I reuse the hardware platform of my non-safety applications for safety applications? +−
Usually, yes. Coded Processing detects hardware faults in software, so it does not need two-channel hardware: the safety function runs on standard (COTS) processors, e.g. x86 or ARM in an industrial PC or a non-safety PLC, with standard Linux distributions or even on bare metal, and the compiler and linker of your choice build your code and the generated C code for it. A safe clock and the black channel (safe communication) are still required, and the platform needs enough computing time and memory for both channels. See what Coded Processing covers and what your platform needs.
How does the SIListra Safety Transformer relate to the CODESYS Virtual Safe Control SL? +−
CODESYS used the SIListra Safety Transformer to develop the TÜV SÜD-certified CODESYS Virtual Safe Control SL, a virtual safety controller for applications up to SIL 3 on standard x86 and ARM hardware. If you use the CODESYS Virtual Safe Control SL, you don’t need the SIListra Safety Transformer: it is a tool for manufacturers who develop their own safety software in C or C++.
What do I still need to do for the certification of my product? +−
The certified tool reduces, but does not remove, your own effort: you need a safety concept for your application, your software must be developed according to an appropriate safety standard, and the SIListra Safety Transformer must be integrated into your toolchain and validated together with your compiler, linker, and target platform. These parts are assessed as part of your product. We support you throughout the entire product cycle, from the safety concept and the development of your safety software to the assessment – see Service & Consulting.
Go to full FAQ page

Would you like to learn more or start a pilot project?

Our experts will help you find the best path for your project – non-binding and confidential.

Start Evaluation
Follow us on: