Automation
For automation: safety PLCs, virtual PLCs, safe sensors and safe communication on standard hardware. Coded Processing decouples certified safety functions from the controller hardware, in machinery and in the process industry.

You build PLCs, safety controllers or virtual PLCs, safe sensors or safe communication components for machinery or the process industry. This is where hardware-bound safety architectures show their age fastest: every new controller generation or virtualization step forces a hardware re-evaluation. Coded Processing decouples the safety function from the specific hardware it runs on.
Focus areas
- Certifiability — the SIListra Safety Transformer is TÜV SÜD-certified for IEC 61508 up to SIL 3, ISO 13849 up to PL e, IEC 62061 up to SIL 3 and, for the process industry, IEC 61511 up to SIL 3 (see Certification & Standards).
- SafePLC & VirtualSafe — safety PLCs on standard hardware and virtual PLCs whose safety logic runs as software, independent of a specific controller model.
- Sensors & safe communication — safety doesn’t end at the controller: the evaluation of high-resolution sensors and safe communication stacks such as FSoE, PROFIsafe or OPC UA Safety can run as encoded software on standard processors. Errors detected by Coded Processing reach the communication partners via the output packages of the safe communication (see Safe fieldbuses & I/O modules).
- Hardware independence — the same safety-critical code base can move to new controller generations without a full redevelopment.
- Sophisticated safety algorithms — the SIListra Safety Transformer 3.0.0 supports floating-point arithmetic, so your controller can run demanding safety algorithms, from sensor fusion to drive control.
- Safety functions — control-flow and data-processing errors are detected at runtime through Coded Processing, without additional redundant hardware.
- Licensability — the SIListra Safety Transformer is available as network and CI build license, fitting standard automation development and CI workflows. Since version 3.0.0, an OEM license lets you integrate it into your own toolchain.
IEC 61131-3 on your PLC
Your customers write their safety applications in IEC 61131-3. As a PLC manufacturer, you have two ways to protect them with Coded Processing:
- “SIListrified” runtime — you transform the runtime of your PLC with the SIListra Safety Transformer, and it executes the IEC 61131-3 programs directly. Only you need the SIListra Safety Transformer, not your customers, which keeps your product simple to deploy. Since version 3.0.0, the SIListrified runtime with its reusable safety blocks can be built once as a verified static library.
- Translation to C/C++ — the IEC 61131-3 program is translated into C/C++ and then transformed with the SIListra Safety Transformer. The SIListra Safety Transformer becomes part of the toolchain you deliver to your customers, and the safety application runs with better performance. This also works for languages based on IEC 61131-3, such as Continuous Function Chart (CFC).
Why SIListra Systems for automation
Classic safety PLCs and redundant CPU architectures solve safety at the hardware level — which means every hardware change is also a safety re-certification event. With Coded Processing, the diagnostic logic lives in the software itself, so the same validated safety function is more portable across hardware platforms and product generations. See the SIListra Safety Transformer for the certified tool, or Coded Processing for how the underlying detection works.
Want to learn more or start a pilot project?
Our experts will help you find the best path for your project – non-binding and confidential.