Integration

Integration of the SIListra Safety Transformer into your development toolchain and validation of the complete toolchain, from the SIListra Safety Transformer to your compiler, linker and target platform.

Toolchain integration Toolchain validation CI/CD

We integrate the SIListra Safety Transformer into your development toolchain and validate the toolchain as a whole. Which languages, compilers and language features the tool supports is summarized below under compiler, toolchain & language features.

From Your Source Code to Two Channels

The SIListra Safety Transformer generates the encoded channel from your C or C++ source code and automatically verifies the generated code. The compiler and linker of your choice build both channels into one safety application that runs on your platform.

Toolchain of the SIListra Safety Transformer: your C or C++ source code, programmed or generated as usual, is the native channel and the input of the SIListra Safety Transformer, which generates the encoded channel as C source code and verifies it automatically. The compiler and linker of your choice build the native and the encoded channel into one safety application, which runs on your platform: one standard processor runs both channels.Your C/C++source codeprogrammed orgenerated as usualSIListra Safety TransformerGenerates the encodedchannel as C source code andverifies it automaticallyNative channelYour safety functionEncoded channelGenerated and verified C codeCompiler andlinker of yourchoicebuild bothchannels into onesafety applicationSafety applicationNative channelEncoded channelYour platform – one standard processor runs both channelsToolchain of the SIListra Safety Transformer: your C or C++ source code, programmed or generated as usual, is the native channel and the input of the SIListra Safety Transformer, which generates the encoded channel as C source code and verifies it automatically. The compiler and linker of your choice build the native and the encoded channel into one safety application, which runs on your platform: one standard processor runs both channels.Your C/C++ source codeprogrammed or generated as usualSIListra Safety TransformerGenerates the encodedchannel as C source code andverifies it automaticallyNative channelYour safety functionEncoded channelGenerated andverified C codeCompiler and linkerof your choicebuild both channels intoone safety applicationSafety applicationNative channelEncoded channelYour platformone standard processorruns both channels

Toolchain integration

Build scripts, CI/CD pipelines including virtual build and test environments, and configuration of the SIListra Safety Transformer tailored to your safety metrics.

Toolchain validation

We validate your complete toolchain, from the SIListra Safety Transformer to your selected compiler, linker, and target platform. A validated toolchain can substantially reduce the testing effort required for the safety application itself.

If you already use open-source C/C++ development tools, we help validate them rather than replace them — module and integration tests, code coverage measurement, dynamic sanitizers, static code checks, requirements specification and tracing, and CI. We also develop and validate open-source toolchains for safety-critical C and C++ development.

Compiler, Toolchain & Language Features

The SIListra Safety Transformer works at source-code level: it generates the encoded channel as C source code and verifies it automatically, and the compiler and linker of your choice build both channels into one safety application. There is no proprietary compiler to switch to.

Languages

C up to C23: integers up to 64 bit, structs and arrays, floating point, all control structures, preprocessor.

C++ up to C++23: classes, templates, virtual methods, constexpr, concepts. Not supported: exceptions, RTTI.

Also supported: dynamic memory management and multi-threading (since version 2.1, see the version history).

Compiler

Compiler builtins that the tool does not support are handled by automatically generated stubs. The toolchain from the SIListra Safety Transformer to your compiler, linker, and target platform is validated as a whole – we can do this validation for you.

Floating Point

Since version 3.0.0: float and double (IEEE 754 single and double precision) in constants, variables, parameters and C++ templates, with all arithmetic operators, comparisons and casts. Exactly IEEE 754 precision, much faster than an encoded soft-float library; rounding mode round-to-nearest ties-to-even. Code that relies on NaN values is not supported.

Developed in the research project SafeFloat, first previewed at SPS 2025. Details in our white paper.

Libraries to be encoded must be available as source code for the encoding. Since version 3.0.0, a safety application can also be built from static libraries – for example a main application plus a safety communication stack or safety runtime delivered as a static library. Once an encoded static library has been built, its source code is no longer needed and doesn’t have to be passed on: the library is verified once as a binary and reused in several safety applications. Libraries may depend on other libraries; dynamically linked libraries are not supported. See our white paper on modular development with static libraries (PDF).

Weighing a Tool's Impact Against Mitigation

IEC 61508-3 Ed. 3 (currently a draft) weighs the possible impact of a software tool on the safety integrity against the measures that detect or prevent errors of the tool.

The Tool Confidence Principle

Tool confidence principle per IEC 61508-3 Ed. 3 (CDV, draft): a balance weighs the potential impact of a tool on the safety integrity – tool error impact class (TIC) and functional safety impact (FSI) – against the mitigation measures – tool error detection (TD) and tool usage for safety (TUS).Potential impact onsafety integrityMitigation measuresTICTool errorimpact classFSIFunctionalsafety impactTDTool errordetectionTUSTool usagefor safetyPrinciple per IEC 61508-3 Ed. 3 (CDV, draft)Tool confidence principle per IEC 61508-3 Ed. 3 (CDV, draft): a balance weighs the potential impact of a tool on the safety integrity – tool error impact class (TIC) and functional safety impact (FSI) – against the mitigation measures – tool error detection (TD) and tool usage for safety (TUS).Potential impacton safetyintegrityMitigationmeasuresTICTool errorimpact classFSIFunctionalsafety impactTDTool error detectionTUSTool usage for safetyPrinciple per IEC 61508-3 Ed. 3 (CDV, draft)

For the SIListra Safety Transformer, these are the measures on your side:

  • Use the Checker: it automatically detects encoding errors of the Transformer in the generated code.
  • Test encoded against native: tests compare the encoded safety function generated by the Transformer with your native safety function.
  • Follow a safety process: develop the safety application according to a safety process.

The SIListra Safety Transformer is a TÜV SÜD-certified tool. How it is classified under ISO 26262 and IEC 61508 is listed in the FAQ: Tool classification per standard.

Next Steps

Would you like to integrate the SIListra Safety Transformer into your toolchain? Contact us to discuss your build and validation setup — non-binding and confidential.

Contact Us
Follow us on: