Coded Processing
Diagnostics in software instead of redundant hardware: Coded Processing detects runtime errors of your safety function on a single standard processor – the technology behind the SIListra Safety Transformer.
- Detects transient and permanent hardware errors and interference from non-safety software
- Diagnostic coverage sufficient for SIL 3 (IEC 61508)
- Runs on standard COTS hardware

Two Channels, One Processor
Coded Processing is the central technology of our certified development tool, the SIListra Safety Transformer. It moves the diagnostics of a safety function from redundant hardware into the software itself.
Native and Encoded Channel at Runtime
The native channel runs the original safety function (safety app), programmed or generated as usual. The encoded channel runs the same function in encoded form, generated by the SIListra Safety Transformer from the source code of the native channel. Both channels run together on the same standard hardware, reaching a diagnostic coverage sufficient for SIL 3 (IEC 61508).
The diagnosis of both channels is propagated to the safe communication (black channel): only the channel merge computes the final output packet, and the packet only gets a valid checksum if the outputs of both channels match and the encoding and the control flow are valid. Every detected error therefore results in an invalid output packet — the communication partner of the safety app detects it and brings the system into the safe state.
Coded Processing thus applies the black-channel principle to computation: processor, memory and operating system are treated as non-safe components that may fail. For the receiver, an error in the sending device looks exactly like a packet corrupted in transmission, so the checks of the safety protocol already handle it.
From Your Source Code to Two Channels
The SIListra Safety Transformer generates the encoded channel from your C or C++ source code and automatically verifies the generated code. The compiler and linker of your choice build both channels into one safety application that runs on your platform.
Coded Processing as a method is not tied to a specific programming language: the focus of the SIListra Safety Transformer is on C and C++, and implementations in other languages are possible. For example, we are working on Rust support for the SIListra Safety Transformer in a research project.
Which Faults Are Detected?
The encoding makes deviations and random hardware faults detectable at runtime. A SIListrified program detects the following faults in its data and control flow:
Transient Faults
Permanent Faults
Interference from Non-Safety Software
Corrupted Calculations
Corrupted Control Flow
Simplified from the Safety Manual of the SIListra Safety Transformer 3.0.0:
Memory, CPU and Bus
Faults in the following components are detected when they affect the execution of the safe application, because the output packets of the encoded and the native channel no longer match (IEC 61508-2, Annex A):
- Volatile memory (RAM)
- CPU: ALU and data path, control logic, registers and internal RAM, address calculation, instruction decoding and execution incl. flag registers, program counter and stack pointer, floating-point unit
- On-chip and digital communication, buses: MMU, DMA, bus arbitration
Faults in sub-components are only detected if their software is also encoded with the SIListra Safety Transformer; faults in the communication only if sender and receiver exchange protected data.
Non-Volatile Memory, Power Supply, Environment
Coded Processing doesn’t monitor these components directly: a fault in them is only detected once it affects the execution of the safe application.
- Non-volatile memory
- Power supply
- External conditions, e.g. temperature
An application-specific analysis checks whether the assumed fault rates hold (PFH calculation).
Timing Faults
The certified use case and its assumptions are described in the Safety Manual of the SIListra Safety Transformer, which is part of the scope of delivery.

Reference: A Safety Soft PLC on One Standard Processor
With Coded Processing, the safety function runs as two logical channels on one standard processor — no second, redundant processor is needed for the diagnostics.
In practice, a TÜV SÜD-certified safety soft PLC already runs safety applications up to SIL 3 (IEC 61508) on standard x86 hardware without two-channel hardware — based on the SIListra Safety Transformer.
Category and Performance Level are always properties of the complete safety function, from sensor to actuator, including I/O, communication, and common cause failures. We determine them together with you as part of your safety concept.
What Coded Processing Covers — and What Stays in the System
Coded Processing protects the execution of the SIListrified program code on the processor. Some parts of a safety function lie outside the encoded code and are considered in your system architecture and safety concept.
Covered by Coded Processing
Runtime diagnostics for the safety-relevant code, realized entirely in software.
Part of Your System Architecture
Measures around the encoded code that bring the system into the safe state.
Standard Hardware, Your Tool Chain
The SIListra Safety Transformer generates C source code, and the compiler and linker of your choice build it. The generated code is therefore platform-independent and runs on standard (COTS) hardware — without necessarily requiring special safety hardware.
COTS Processors
Virtual Controllers
Standard Linux or Bare Metal
Questions About Your Platform
Which operating system?
The operating system you use and its role in the safety argument are part of your system architecture. Tell us about your intended platform, and we will discuss its suitability with you.
How much performance does it cost?
The encoded channel runs in addition to the native channel, so a SIListrified safety function needs more computing time and memory. How much depends on your application — so we measure it with your code.
Publications & Patents
Our technical papers, talks, trade press articles, and patents explain Coded Processing and its control flow protection in detail.
Go to Publications & PatentsDoes Coded Processing fit your architecture?
Tell us about your application, standard, and target platform — one of our engineers will assess it with you, non-binding and confidential.
Start Evaluation