FAQ & Glossary

Glossary and answers to the questions we hear most often about Coded Processing, certification, and integration.

Frequently Asked Questions Glossary

Common Questions

What is actually certified? +−
The SIListra Safety Transformer – the development tool itself – is a TÜV SÜD-certified tool in version 3.0.0. The certification covers the tool (including its development process) and the Diversified Encoding use case described in its safety manual, for IEC 61508 (edition 2 and CDV of edition 3) up to SIL 3, ISO 26262 up to ASIL D, ISO 13849 up to PL e (Cat. 3 and 4), IEC 62061 up to SIL 3, and IEC 61511 up to SIL 3. See Certification & Standards for the full list and how to request the certificate, and the tool classification per standard.
How is the SIListra Safety Transformer classified as a tool? +−

The SIListra Safety Transformer – the Transformer and the Checker – is considered as a whole: for each standard, the higher class of the two applies. The classification applies if the correct function of the generated encoded channel is ensured by running module tests.

  • ISO 26262: TCL3
  • IEC 61508, 2nd edition (2010): T3
  • IEC 61508, 3rd edition (CDV, draft): TUS 2 for safety functions with FSI 3 (up to SIL 3), TUS 1 with FSI 1 or 2 – the FSI (functional safety impact) follows from the SIL of your safety function.

See Certification & Standards for the certificate and the covered standards.

Which standards does the certificate cover for my industry? +−
The SIListra Safety Transformer is TÜV SÜD-certified for IEC 61508 up to SIL 3 as the generic standard; for machinery, ISO 13849 up to PL e (Cat. 3 and 4) and IEC 62061 up to SIL 3; for the process industry, IEC 61511 up to SIL 3; and for road vehicles, ISO 26262 up to ASIL D. See Certification & Standards.
What do I still need to do for the certification of my product? +−
The certified tool reduces, but does not remove, your own effort: you need a safety concept for your application, your software must be developed according to an appropriate safety standard, and the SIListra Safety Transformer must be integrated into your toolchain and validated together with your compiler, linker, and target platform. These parts are assessed as part of your product. We support you throughout the entire product cycle, from the safety concept and the development of your safety software to the assessment – see Service & Consulting.
Which architecture does Coded Processing use? +−
Coded Processing runs two logical channels on the same standard hardware: the native channel, which runs your original safety function as programmed, and the encoded channel, which the SIListra Safety Transformer generates automatically from the native channel’s source code. Both channels run together and reach a sufficiently high diagnostic coverage for SIL 3 (IEC 61508). See Coded Processing for the full explanation and architecture diagram.
What happens when a bit flips? +−
Coded Processing is designed to detect three classes of runtime errors in the SIListrified program code: transient errors (e.g. a single bit flip caused by radiation or electrical interference), permanent errors (persistent hardware faults), and interference from non-safety software (e.g. the operating system, according to IEC 61508 Annex F). Detected errors are propagated to the output packets of the safe communication (black channel), so they are handled by the communication partners of the safety application – the same mechanism used for any other detected safety fault.
Coded Processing at runtime when a bit flips, along the error path: 1. a bit flips in the encoded channel; 2. the native and the encoded channel no longer agree; 3. so the channel merge produces no valid checksum, and the output packet sent over the black channel is invalid; 4. the actuator or receiver detects the invalid packet and goes to the safe state.SensorBlack ChannelInput packetSafety appNative channelYour safety functionEncoded channelGenerated by the SIListra Safety Transformer1Channelmerge+ checksum23Valid checksum only if both channels agreeand encoding and control flow are correctBlack ChannelOutput packetActuator /receiver→ safe state4Non-safety appsHypervisorStandard platform (COTS) – no certified operating system requiredError path1Bit flip2Channels disagree3Checksum invalid4Safe stateCoded Processing at runtime when a bit flips, along the error path: 1. a bit flips in the encoded channel; 2. the native and the encoded channel no longer agree; 3. so the channel merge produces no valid checksum, and the output packet sent over the black channel is invalid; 4. the actuator or receiver detects the invalid packet and goes to the safe state.SensorBlack ChannelInput packetSafety appNative channelYour safety functionEncoded channelGenerated by the SIListraSafety Transformer1Channelmerge+ checksum23Valid checksum only if both channelsagree and encoding and control floware correctBlack ChannelOutput packetActuator / receiver→ safe state4Safety appNon-safety appsHypervisorStandard platform (COTS)no certified operating system requiredError path1Bit flip2Channels disagree3Checksum invalid4Safe state
Can I reach SIL 3 or ISO 13849 Category 3 with a single CPU? +−
Yes. With Coded Processing, the safety function runs as a native and an encoded channel on one standard processor and reaches a sufficiently high diagnostic coverage for SIL 3 (IEC 61508); for ISO 13849, the tool is certified up to PL e with Category 3, and Category 4 is possible as well. Category and Performance Level are properties of your complete safety function, including I/O and communication, so they are settled in your safety concept. See Coded Processing.
What still has to be solved in hardware? +−
Coded Processing protects the execution of the SIListrified code on the processor. Safe communication (black channel), safe I/O, a safe time source, and the safe handling of communication errors are part of your system architecture. See what Coded Processing covers and tool vs. system certification.
Can I reuse the hardware platform of my non-safety applications for safety applications? +−
Usually, yes. Coded Processing detects hardware faults in software, so it does not need two-channel hardware: the safety function runs on standard (COTS) processors, e.g. x86 or ARM in an industrial PC or a non-safety PLC, with standard Linux distributions or even on bare metal, and the compiler and linker of your choice build your code and the generated C code for it. A safe clock and the black channel (safe communication) are still required, and the platform needs enough computing time and memory for both channels. See what Coded Processing covers and what your platform needs.
Does it run on COTS hardware with ARM or x86, and on Linux? +−
Yes. The SIListra Safety Transformer generates platform-independent C code that the compiler and linker of your choice build for your target processor/platform, e.g. standard (COTS) hardware with x86 or ARM application processors. No certified operating system is required: the safety function runs on standard Linux distributions or even on bare metal. The SIListra Safety Transformer itself runs on your development host under Windows and Linux, also in Docker. See Platforms.
How much performance does Coded Processing cost? +−
The encoded channel runs in addition to the native channel, so the safety function needs more computing time and memory. How much depends on your application, so we measure it with your code in a performance or pilot project. See Resources and performance.
Are there requirements on the compiler? Is floating point supported? +−
You keep the compiler and linker of your choice; the toolchain from the SIListra Safety Transformer to your target platform is validated as a whole. Since version 3.0.0, the SIListra Safety Transformer supports floating-point types and arithmetic in addition to integer types up to 64 bits, based on our SafeFloat research project. For floating point, your compiler must generate IEEE 754-conformant code: the user manual describes the settings for several platforms, and hardware behavior that doesn’t conform to IEEE 754 is diagnosed at runtime. See Compiler, toolchain & language features.
Which libraries are supported? +−
The SIListra Safety Transformer encodes your safety function at source-code level, so the C/C++ libraries it uses are encoded along with it: for the encoding, they must be available as source code. The exception are the mathematical functions of the C standard library, such as sin or sqrt: for them, the SIListra Safety Math Library provides verified, pre-encoded functions for both channels. Since version 3.0.0, an encoded library can be built once as a static library: after that, its source code is no longer needed and doesn’t have to be passed on, and the encoded static library can be reused as a binary in several safety applications. Libraries may depend on other libraries; dynamically linked libraries are not supported.
Does the generated code need to be reviewed or tested? +−
The encoded channel needs no manual review or static analysis: the Checker, part of the SIListra Safety Transformer, verifies the correct encoding of the generated code automatically. Your safety application still has to be tested, as any safety software. The SIListra Unit Testing Library makes this easier: your existing GoogleTest tests that use its supported feature set also test the encoded channel, unchanged, and report the results of both channels in one run.
Can I use my own safety I/O modules and protocol stacks? +−
Yes. Detected errors are propagated to the output packets of the safe communication (black channel), so your safety I/O modules act as communication partners and bring the system into the safe state. We implement stacks such as FSoE, PROFIsafe, and OPC UA Safety or integrate your existing one: even a pre-certified stack can in most cases be encoded without changes to its source code, only its integration is adapted, e.g. merging the output packets of both channels into a single packet. Our demonstrator based on the HMS FSoE stack uses the stack as it is, so its certificate stays valid. See Safe fieldbuses & I/O modules.
How does the SIListra Safety Transformer relate to the CODESYS Virtual Safe Control SL? +−
CODESYS used the SIListra Safety Transformer to develop the TÜV SÜD-certified CODESYS Virtual Safe Control SL, a virtual safety controller for applications up to SIL 3 on standard x86 and ARM hardware. If you use the CODESYS Virtual Safe Control SL, you don’t need the SIListra Safety Transformer: it is a tool for manufacturers who develop their own safety software in C or C++.
Is it possible to discuss my requirements first or to receive additional information? +−
Of course: contact us and talk to one of our engineers by phone or in a video meeting, e.g. on Microsoft Teams. Our information material is available right away.

Terms Used Across This Site

Coded Processing

Our method of instrumenting diagnostic error detection directly into a program's source code, avoiding the need for redundant hardware. See Coded Processing.

Native channel

The original, unmodified safety function as programmed or generated by the developer. See how Coded Processing works.

Encoded channel

The diagnostic counterpart to the native channel, generated automatically by the SIListra Safety Transformer.

Checker

The component of the SIListra Safety Transformer that automatically verifies the generated encoded channel source code, removing the need for manual review. See Certification & Standards.

Black channel

The communication path between the safety application and its partners, which by itself provides no safety guarantees; a safety protocol on top (e.g. FSoE, PROFIsafe) makes the communication safe. Detected errors are passed through it to the communication partners. See what Coded Processing covers.

Diagnostic coverage

The proportion of possible faults a safety mechanism can detect; SIL 3 (IEC 61508) requires a sufficiently high diagnostic coverage, which Coded Processing is designed to achieve on standard hardware. See how Coded Processing works.

T1–T3 / TCL1–TCL3

Tool classifications of two safety standards. IEC 61508 (2nd edition) sorts off-line support tools into the classes T1 to T3: T3 are tools whose output becomes part of the executable code, such as compilers and code generators. ISO 26262 assigns a tool confidence level (TCL1 to TCL3), derived from the possible impact of a tool error and the probability that it is detected; TCL3 requires the most qualification measures. See Tool classification.

TUS (Tool Usage for Safety)

The risk-based tool classification of the 3rd edition of IEC 61508-3 (currently a draft), from TUS 1 to TUS 4: the minimum tool usage for safety follows from the impact of a tool error (TIC), the functional safety impact (FSI) and how effectively the user's measures detect or prevent tool errors (TD). See Tool classification.

Software-Defined Safety

Functional safety as a software feature: safety functions run as software on standard hardware instead of being bound to special safety hardware, so they can be ported, reused and developed further like any other software. See the SIListra Safety Transformer.

Publications & Patents

Want to go deeper than the FAQ? Our technical papers, talks, trade press articles, and patents explain Coded Processing and its control flow protection in detail.

Go to Publications & Patents

Didn't find your answer? Contact us directly.

Follow us on: