FAQ & Glossary
Glossary and answers to the questions we hear most often about Coded Processing, certification, and integration.

Common Questions
What is actually certified?
How is the SIListra Safety Transformer classified as a tool?
The SIListra Safety Transformer – the Transformer and the Checker – is considered as a whole: for each standard, the higher class of the two applies. The classification applies if the correct function of the generated encoded channel is ensured by running module tests.
- ISO 26262: TCL3
- IEC 61508, 2nd edition (2010): T3
- IEC 61508, 3rd edition (CDV, draft): TUS 2 for safety functions with FSI 3 (up to SIL 3), TUS 1 with FSI 1 or 2 – the FSI (functional safety impact) follows from the SIL of your safety function.
See Certification & Standards for the certificate and the covered standards.
Which standards does the certificate cover for my industry?
What do I still need to do for the certification of my product?
Which architecture does Coded Processing use?
What happens when a bit flips?
Can I reach SIL 3 or ISO 13849 Category 3 with a single CPU?
What still has to be solved in hardware?
Can I reuse the hardware platform of my non-safety applications for safety applications?
Does it run on COTS hardware with ARM or x86, and on Linux?
How much performance does Coded Processing cost?
Are there requirements on the compiler? Is floating point supported?
Which libraries are supported?
sin or sqrt: for them, the SIListra Safety Math Library provides verified, pre-encoded functions for both channels. Since version 3.0.0, an encoded library can be built once as a static library: after that, its source code is no longer needed and doesn’t have to be passed on, and the encoded static library can be reused as a binary in several safety applications. Libraries may depend on other libraries; dynamically linked libraries are not supported.Does the generated code need to be reviewed or tested?
Can I use my own safety I/O modules and protocol stacks?
How does the SIListra Safety Transformer relate to the CODESYS Virtual Safe Control SL?
Is it possible to discuss my requirements first or to receive additional information?
Terms Used Across This Site
Our method of instrumenting diagnostic error detection directly into a program's source code, avoiding the need for redundant hardware. See Coded Processing.
The original, unmodified safety function as programmed or generated by the developer. See how Coded Processing works.
The diagnostic counterpart to the native channel, generated automatically by the SIListra Safety Transformer.
The component of the SIListra Safety Transformer that automatically verifies the generated encoded channel source code, removing the need for manual review. See Certification & Standards.
The communication path between the safety application and its partners, which by itself provides no safety guarantees; a safety protocol on top (e.g. FSoE, PROFIsafe) makes the communication safe. Detected errors are passed through it to the communication partners. See what Coded Processing covers.
The proportion of possible faults a safety mechanism can detect; SIL 3 (IEC 61508) requires a sufficiently high diagnostic coverage, which Coded Processing is designed to achieve on standard hardware. See how Coded Processing works.
Tool classifications of two safety standards. IEC 61508 (2nd edition) sorts off-line support tools into the classes T1 to T3: T3 are tools whose output becomes part of the executable code, such as compilers and code generators. ISO 26262 assigns a tool confidence level (TCL1 to TCL3), derived from the possible impact of a tool error and the probability that it is detected; TCL3 requires the most qualification measures. See Tool classification.
The risk-based tool classification of the 3rd edition of IEC 61508-3 (currently a draft), from TUS 1 to TUS 4: the minimum tool usage for safety follows from the impact of a tool error (TIC), the functional safety impact (FSI) and how effectively the user's measures detect or prevent tool errors (TD). See Tool classification.
Functional safety as a software feature: safety functions run as software on standard hardware instead of being bound to special safety hardware, so they can be ported, reused and developed further like any other software. See the SIListra Safety Transformer.
Publications & Patents